WinActor FAQ
Result
-
"Failed to start the browser. ..."
Please refer to attached manual, "WinActor Browser Operation Scenario Creation Manual, 4. Procedure to install WebDriver." to update/reinstall the WebDriver wi… -
Please let me know about the compatibility of the scenario file.
Scenarios for older versions can also be run with WinActor Ver.7.1.1. (So-called Backward compatibility.) The scenario file formats supported by each version o… -
Does WinActor work under the virtualized environment?
WinActor can be installed in a virtual environment or thin-client. However, the license may not work properly (* 1) in an environment where the PC information i… -
To save data which is displayed in the Data Table screen.
When you operate with the following procedures, the dialog "Data in the data list has been changed. Do you want to save the changes?" is displayed, and you can… -
In Chrome mode, recording cannot be performed.
■ Operation workaround If this event occurs, stop recording, select the recording target again, and start recording again. -
About relative path of "Excel" node.
Here are workarounds: (1) If the paths of scenario file and the Excel file will not change, manually specify the full path in the file name input field. (2) Us… -
Can it be used with Firefox and Chrome as well as IE?
In case of Ver.5.x.x, browser related features were introduced, and operations using Chrome, Firefox, Edge object recognition became possible. In case of Ver.6… -
Can I record touch panel operations with OR-5200?
Recording touch panel operation has not supported yet, but if you can substitute the touching operations with keyboard or mouse operations, there is no problem… -
The change of the window title in IE mode or event mode.
■ Operation workaround When changing the recording mode from IE or event mode to emulation mode for the same window, select the target window from the window l… -
Acrobat Reader window cannot be selected.
Please confirm that you have cancelled the protection mode of AcrobatReader. Note: the restrictions of OR-5200 are listed in the manuals of OR-5200. Please als… -
It takes extremely long time to verify the actions upon failure or to identify such a Node.
When any error occurs, the caused Node is highlighted. The variable in suspicion can be found in Property window, which can be opened by double-click on the No… -
"You cannot register more than 51 monitoring rules."
The maximum number of monitoring rules is 50. When adding manually, it is not possible to add more than 50. Because there is no upper limit check in the scenar… -
It happens to be unable to select the application while recording operation.
It does not seem to be a bug or defect in OR-5200 itself. Some cases have been identified as follows: 1. When recording scenario by IE Mode through WiFi, Mobil… -
Is private variables available in WinActor?
In WinActor there are two types of variables. One is a public (global) type, the other is a private(local) type. The private variable called local variable in W… -
Is there any solution for using string having more than 1024 characters?
As there is no means for Ver.5, upgrade to Ver. 6.1.0 is required. Although the default settings of Ver.6.1.0 is the same as that of Ver.5, i.e. up to 1024 cha… -
It fails to open the file.
It may be because it took a long time to move the file, and you tried to open the file before the file transfer was completed. Please correct the scenario so t… -
Is there any limit to the number of scenarios that can be created and saved?
There is no limit to the number of scenarios that can be created and saved. -
Is there any means to safely use password entry and management in OR-5200 scenarios?
The variable masking is a function only to make variable invisible in the variable list, whereas it is visible by displaying the variable in Message_Box, etc. … -
An unintended line break was inserted when using "Send_Text" of a node.
This issue may occur because the Send return key check box in the Send_Text option is selected. Follow the procedure below to remove the check box and check th… -
Image matching fails because of screens overlapping.
Usually, image matching brings the target screen to the front during runtime, but for some reason the image matching may bring other screen to the front instea…
- 1-20 displayed / 33 results found
- Previous1

