WinActor FAQ
Result
-
Scenarios for older versions can also be run with WinActor Ver.7.1.1. (So-called Backward compatibility.) The scenario file formats supported by each version o…
-
The variable masking is a function only to make variable invisible in the variable list, whereas it is visible by displaying the variable in Message_Box, etc. …
-
WinActor can be installed in a virtual environment or thin-client. However, the license may not work properly (* 1) in an environment where the PC information i…
-
Please confirm that you have cancelled the protection mode of AcrobatReader. Note: the restrictions of OR-5200 are listed in the manuals of OR-5200. Please als…
-
When any error occurs, the caused Node is highlighted. The variable in suspicion can be found in Property window, which can be opened by double-click on the No…
-
Please refer to attached manual, "WinActor Browser Operation Scenario Creation Manual, 4. Procedure to install WebDriver." to update/reinstall the WebDriver wi…
-
Recording touch panel operation has not supported yet, but if you can substitute the touching operations with keyboard or mouse operations, there is no problem…
-
When you operate with the following procedures, the dialog "Data in the data list has been changed. Do you want to save the changes?" is displayed, and you can…
-
In case of Ver.5.x.x, browser related features were introduced, and operations using Chrome, Firefox, Edge object recognition became possible. In case of Ver.6…
-
The maximum number of monitoring rules is 50. When adding manually, it is not possible to add more than 50. Because there is no upper limit check in the scenar…
-
Please use the library "CountLinesInFile". To remove the header line, subtract -1 from the resulting value. In case of Excel, please use the library"GetLastRow…
-
As there is no means for Ver.5, upgrade to Ver. 6.1.0 is required. Although the default settings of Ver.6.1.0 is the same as that of Ver.5, i.e. up to 1024 cha…
-
In WinActor there are two types of variables. One is a public (global) type, the other is a private(local) type. The private variable called local variable in W…
-
There is no limit to the number of scenarios that can be created and saved.
-
■ Operation workaround When changing the recording mode from IE or event mode to emulation mode for the same window, select the target window from the window l…
-
Usually, image matching brings the target screen to the front during runtime, but for some reason the image matching may bring other screen to the front instea…
-
It does not seem to be a bug or defect in OR-5200 itself. Some cases have been identified as follows: 1. When recording scenario by IE Mode through WiFi, Mobil…
-
■ Operation workaround If this event occurs, stop recording, select the recording target again, and start recording again.
-
It may be because it took a long time to move the file, and you tried to open the file before the file transfer was completed. Please correct the scenario so t…
-
This issue may occur because the Send return key check box in the Send_Text option is selected. Follow the procedure below to remove the check box and check th…
- 1-20 displayed / 33 results found
- Previous1